Power

Low Voltage Power Cables

Approvals available VDE · HAR · BASEC · NF (LCIE) · KEMA-KEUR · CEBEC · UL · TÜV · TSE / TSEK · IMQ · AENOR

NYM (YM)
VDE 0250-204 · TS EN 50525-2-31 · IEC 60227 · UL 83 · BS 6004 · EN 50575 (CPR)
Configure NYM (YM)
NYIFY
VDE 0250 · TS 98
Configure NYIFY
NYY (VV)
IEC 60502-1 · VDE 0276-603 · TS EN 60228 · UL 1277 · BS 5467 · EN 50575 (CPR)
Configure NYY (VV)
NYRY
IEC 60502-1 · VDE 0276 · TS IEC 60502-1 · BS 5467
Configure NYRY
NYBY
IEC 60502-1 · VDE 0276 · TS IEC 60502-1 · BS 5467
Configure NYBY
H07V-U / H07V-R (building wire)
TS EN 50525-2-31 · IEC 60227-3 · VDE 0281-3 · BS 6004 · EN 50575 (CPR)
Configure H07V-U / H07V-R (building wire)
H05V-K / H07V-K (flexible wire)
TS EN 50525-2-31 · IEC 60227-3 · VDE 0281-3 · BS 6004 · EN 50575 (CPR)
Configure H05V-K / H07V-K (flexible wire)
NAYY (aluminium)
IEC 60502-1 · VDE 0276-603 · TS IEC 60502-1
Configure NAYY (aluminium)
NA2XY (aluminium, XLPE)
IEC 60502-1 · VDE 0276-603 · TS IEC 60502-1
Configure NA2XY (aluminium, XLPE)
NYCY / NYCWY (concentric)
IEC 60502-1 · VDE 0276-603 · EN 50575 (CPR)
Configure NYCY / NYCWY (concentric)
NYMÖ (oil-resistant)
VDE 0276 · TS IEC 60502-1
Configure NYMÖ (oil-resistant)
N2XY / YXV (copper, XLPE)
IEC 60502-1 · VDE 0276-603 · TS IEC 60502-1 · EN 50575 (CPR)
Configure N2XY / YXV (copper, XLPE)
N2XRY / N2XFGbY (XLPE, steel wire armoured)
IEC 60502-1 · VDE 0276-603 · TS IEC 60502-1
Configure N2XRY / N2XFGbY (XLPE, steel wire armoured)
NYFGbY (PVC, flat steel wire armoured)
IEC 60502-1 · VDE 0276-603 · TS IEC 60502-1
Configure NYFGbY (PVC, flat steel wire armoured)
N2XCY (XLPE, concentric screen)
IEC 60502-1 · VDE 0276-603 · TS IEC 60502-1
Configure N2XCY (XLPE, concentric screen)
BS 5467 armoured (Cu/XLPE/SWA/PVC)
BS 5467 · IEC 60502-1 · EN 50575 (CPR)
Configure BS 5467 armoured (Cu/XLPE/SWA/PVC)
BS 6724 armoured LSZH (Cu/XLPE/SWA/LSHF)
BS 6724 · IEC 60502-1 · EN 50575 (CPR)
Configure BS 6724 armoured LSZH (Cu/XLPE/SWA/LSHF)
BS 6004 6242Y / 6491X (twin & earth, single core)
BS 6004 · EN 50575 (CPR)
Configure BS 6004 6242Y / 6491X (twin & earth, single core)
H05V2-K / H07V2-K (90 °C heat-resistant)
TS EN 50525-2-31 · IEC 60227-3 · EN 50575 (CPR)
Configure H05V2-K / H07V2-K (90 °C heat-resistant)
Configure this family

Medium Voltage Power Cables

Approvals available VDE · BASEC · NF (LCIE) · KEMA-KEUR · CEBEC · UL · TÜV · TSE / TSEK

YXV (XV) / N2XSY
IEC 60502-2 · VDE 0276-620 · TS IEC 60502-2 · UL 1072 · BS 6622
Configure YXV (XV) / N2XSY
Y2XY
IEC 60502-2 · VDE 0276
Configure Y2XY
YE3SV
IEC 60502-2 · BS 6622
Configure YE3SV
AXV-R
IEC 60502-2 · NF C 33-226
Configure AXV-R
NA2XS(F)2Y (aluminium)
IEC 60502-2 · VDE 0276-620 · TS IEC 60502-2
Configure NA2XS(F)2Y (aluminium)
N2XSEY / NA2XSEY (three-core)
IEC 60502-2 · VDE 0276-620 · TS IEC 60502-2
Configure N2XSEY / NA2XSEY (three-core)
N2XSRY / NA2XSRY (armoured)
IEC 60502-2 · VDE 0276-620 · BS 6622
Configure N2XSRY / NA2XSRY (armoured)
N2XS(FL)2Y (water-blocked, Al laminate)
IEC 60502-2 · VDE 0276-620 · TS IEC 60502-2
Configure N2XS(FL)2Y (water-blocked, Al laminate)
Configure this family

Overhead Line Conductors (Bare)

Approvals available KEMA-KEUR · TSE / TSEK

AAC
IEC 61089 · EN 50182 · BS 215-1 · DIN 48201-5 · ASTM B231
Configure AAC
AAAC
IEC 61089 · EN 50182 · BS 3242 · ASTM B399
Configure AAAC
ACSR
IEC 61089 · EN 50182 · BS 215-2 · DIN 48204 · ASTM B232
Configure ACSR
AACSR
IEC 61089 · EN 50182 · ASTM B711
Configure AACSR
ACSR/AW
IEC 61089 · ASTM B549
Configure ACSR/AW
ACCC (HTLS)
ASTM B987 · Customer specification
Configure ACCC (HTLS)
OPGW (optical ground wire)
IEC 60794-4-10 · IEEE 1138
Configure OPGW (optical ground wire)
Bare Copper Conductor (overhead / earthing)
IEC 60228 · EN 13602 · TS 3 · ASTM B8
Configure Bare Copper Conductor (overhead / earthing)
Configure this family

Aerial Bundled Cables & Covered Conductors

Approvals available VDE · NF (LCIE) · KEMA-KEUR · TSE / TSEK

LV Aerial Bundled Cable (ABC)
HD 626 · NF C 33-209 · BS 7870-5 · TS IEC 60502-1
Configure LV Aerial Bundled Cable (ABC)
LV ABC with Insulated Messenger
HD 626 · BS 7870-5
Configure LV ABC with Insulated Messenger
MV Aerial Bundled Cable
HD 620 · IEC 60502-2
Configure MV Aerial Bundled Cable
MV Covered Conductor
EN 50397-1
Configure MV Covered Conductor
Configure this family

Fire performance

LSZH (Halogen-Free) Cables

Approvals available VDE · HAR · BASEC · NF (LCIE) · KEMA-KEUR · CEBEC · UL · TÜV · TSE / TSEK · IMQ · AENOR

H07Z-R / H07Z-U
TS EN 50525-3-41 · IEC 60332-3 · VDE 0282 · BS 7211 · UL 44 (XHHW-2) · EN 50575 (CPR)
Configure H07Z-R / H07Z-U
NHXMH
DIN VDE 0250-215 · BS 7211 · UL 758 · EN 50575 (CPR)
Configure NHXMH
N2XH
IEC 60502-1 · DIN VDE 0276-604 · BS 6724 · EN 50575 (CPR)
Configure N2XH
NHXCH
DIN VDE 0276-604 · IEC 60502-1 · EN 50575 (CPR)
Configure NHXCH
Configure this family

Fire Resistant / Flame Retardant Cables

Approvals available VDE · BASEC · NF (LCIE) · KEMA-KEUR · CEBEC · LPCB · MPA NRW · TÜV · TSE / TSEK · IMQ · AENOR

NHXH FE180/E30
DIN VDE 0276-604 · IEC 60331 · DIN 4102-12 · BS 6387 CWZ · EN 50575 (CPR)
Configure NHXH FE180/E30
NHXH FE180/E90
DIN VDE 0276-604 · IEC 60331 · DIN 4102-12 · EN 50575 (CPR)
Configure NHXH FE180/E90
JE-H(St)H FE180
DIN VDE 0815 · IEC 60331-21 · BS 5308 · EN 50575 (CPR)
Configure JE-H(St)H FE180
LIHCH FE180 (screened, halogen-free)
IEC 60331-21 · EN 50575 (CPR)
Configure LIHCH FE180 (screened, halogen-free)
LIH(St)H FE180 (foil screened, halogen-free)
IEC 60331-21 · EN 50575 (CPR)
Configure LIH(St)H FE180 (foil screened, halogen-free)
Fire alarm cable PH120 (BS 7629-1 / EN 50200)
BS 7629-1 · EN 50200 · BS 6387 CWZ · EN 50575 (CPR)
Configure Fire alarm cable PH120 (BS 7629-1 / EN 50200)
Configure this family

CPR-Classified Building Cables (EN 50575)

Approvals available VDE · HAR · BASEC · NF (LCIE) · KEMA-KEUR · CEBEC · TSE / TSEK · IMQ · AENOR

H07Z1-K Type 2
EN 50525-3-41 · EN 50575 (CPR)
Configure H07Z1-K Type 2
FG16OM16
CEI 20-13 · EN 50575 (CPR)
Configure FG16OM16
FG18OM16
CEI 20-13 · EN 50575 (CPR)
Configure FG18OM16
FG16R16
CEI 20-13 · EN 50575 (CPR)
Configure FG16R16
FG16OR16
CEI 20-13 · EN 50575 (CPR)
Configure FG16OR16
RZ1-K (AS)
UNE 21123-4 · EN 50575 (CPR)
Configure RZ1-K (AS)
U-1000 R2V
NF C 32-321 · EN 50575 (CPR)
Configure U-1000 R2V
U-1000 AR2V (aluminium)
NF C 32-321 · EN 50575 (CPR)
Configure U-1000 AR2V (aluminium)
Configure this family

Industrial

Rubber & Flexible Industrial Cables

Approvals available VDE · HAR · BASEC · KEMA-KEUR · UL · TÜV · TSE / TSEK

H07RN-F
EN 50525-2-21 · IEC 60245-4 · VDE 0282-4 · UL 62 (SOOW)
Configure H07RN-F
H05RR-F
EN 50525-2-21 · IEC 60245-2
Configure H05RR-F
NSGAFÖU
VDE 0250-602
Configure NSGAFÖU
N07V3-K
VDE 0281 · HD 21.3
Configure N07V3-K
H01N2-D / H01N2-E (welding)
EN 50525-2-81 · VDE 0282-6
Configure H01N2-D / H01N2-E (welding)
NSHTÖU (drum reeling)
DIN VDE 0250-814 · IEC 60228
Configure NSHTÖU (drum reeling)
Configure this family

Heavy-Duty Industrial Cables

Approvals available VDE · HAR · BASEC · KEMA-KEUR · TSE / TSEK

NYMHY
VDE 0281 · TS 9758
Configure NYMHY
NYIFY Flexible
VDE 0250 · TS 98
Configure NYIFY Flexible
A05VV-U
VDE 0281 · HD 21.4
Configure A05VV-U
H03VV-F / H05VV-F (flexible cord)
TS EN 50525-2-11 · IEC 60227-5 · VDE 0281-5
Configure H03VV-F / H05VV-F (flexible cord)
H03V2V2-F / H05V2V2-F (90 °C flexible cord)
TS EN 50525-2-12 · IEC 60227-5
Configure H03V2V2-F / H05V2V2-F (90 °C flexible cord)
Configure this family

Renewables

Control & data

Control & Instrumentation Cables

Approvals available VDE · BASEC · UL · TÜV · TSE / TSEK

LiYY
DIN 47100 · VDE 0812 · TS EN 60228 · UL 2464
Configure LiYY
LiYCY
DIN 47100 · VDE 0812 · UL 2919
Configure LiYCY
LIHH
DIN 47100
Configure LIHH
RE-2Y(St)Yv
EN 50288-7 · BS 5308 Part 1 & 2
Configure RE-2Y(St)Yv
YSLY-JZ (flexible control, numbered cores)
VDE 0245 · EN 50525-2-51 · IEC 60227
Configure YSLY-JZ (flexible control, numbered cores)
YSLCY-JZ (screened flexible control)
VDE 0245 · EN 50525-2-51 · IEC 60227
Configure YSLCY-JZ (screened flexible control)
05VV-F / 07VV-F (60227 IEC 71c control)
IEC 60227-4 · TS EN 50525-2-51
Configure 05VV-F / 07VV-F (60227 IEC 71c control)
NYY-J / N2XY-J control (5–61 cores)
IEC 60502-1 · VDE 0276-603 · TS IEC 60502-1
Configure NYY-J / N2XY-J control (5–61 cores)
Instrumentation cable (BS 5308 / EN 50288-7)
BS 5308 Part 1 & 2 · EN 50288-7 · PAS 5308 · IEC 60331-21
Configure Instrumentation cable (BS 5308 / EN 50288-7)
Configure this family

Telecommunication & Data Cables

Approvals available VDE · TSE / TSEK

JE-Y(St)Y
DIN VDE 0815 · VDE 0815 · EN 50575 (CPR)
Configure JE-Y(St)Y
CAT6 UTP/STP
ANSI/TIA-568-C.2 · ISO/IEC 11801 · IEC 61156-5 · EN 50575 (CPR)
Configure CAT6 UTP/STP
CAT5e
ANSI/TIA-568-C.2 · ISO/IEC 11801 · EN 50575 (CPR)
Configure CAT5e
Telephone Distribution (PDV)
TS 1195 · VDE 0816
Configure Telephone Distribution (PDV)
CAT6A F/UTP
ANSI/TIA-568-C.2 · ISO/IEC 11801 · IEC 61156-5 · EN 50575 (CPR)
Configure CAT6A F/UTP
CAT7 S/FTP
ISO/IEC 11801 · IEC 61156-5 · EN 50575 (CPR)
Configure CAT7 S/FTP
JE-H(St)H Bd (fire alarm, CPR)
DIN VDE 0815 · EN 50575 (CPR)
Configure JE-H(St)H Bd (fire alarm, CPR)
J-Y(St)Y (indoor telephone)
DIN VDE 0815 · VDE 0815
Configure J-Y(St)Y (indoor telephone)
Profibus DP
IEC 61158 · EN 50170
Configure Profibus DP
RS-485 bus cable (LI2Y(St)CH)
TIA-485-A · DIN 47100
Configure RS-485 bus cable (LI2Y(St)CH)
KNX / EIB bus cable (YCYM)
EN 50090 · KNX specification
Configure KNX / EIB bus cable (YCYM)
Configure this family

Fibre Optic Cables

Approvals available TSE / TSEK

Loose Tube Underground / Duct
IEC 60794-3-10 · ITU-T G.652 · TS EN 60794-3
Configure Loose Tube Underground / Duct
ADSS Aerial (Self-Supporting)
IEC 60794-4-20 · IEEE 1222
Configure ADSS Aerial (Self-Supporting)
Figure-8 Aerial with Messenger
IEC 60794-3-20 · ITU-T G.652
Configure Figure-8 Aerial with Messenger
Indoor / Indoor-Outdoor (LSZH)
IEC 60794-2 · EN 50575 (CPR)
Configure Indoor / Indoor-Outdoor (LSZH)
FTTH Drop Cable
IEC 60794-3 · ITU-T G.657
Configure FTTH Drop Cable
Armoured Fibre (SWA / corrugated steel)
IEC 60794-3-10 · ITU-T G.652 · EN 50575 (CPR)
Configure Armoured Fibre (SWA / corrugated steel)
Configure this family

Marine

Special

Standards are specification references, not a blanket certification claim. Approvals are available through our partner network, subject to a final verification with the partner manufacturer by Turkish Cables, and are confirmed in each offer.

Not listed?

Send your cable schedule and we will source it.

Send a cable schedule
Configure cable Send schedule